Product Manager Messages
A-3
Product Manager Messages
C
Message Cannot disable Switch Binding while Enterprise Fabric Mode is
active and the switch is Online.
Description User attempted to disable switch binding through the Switch Binding
Change State dialog box, but Enterprise Fabric Mode is enabled.
Action You must either disable Enterprise Fabric Mode using the Enterprise
Fabric Mode dialog box in the EFC Manager application or set the
switch offline before you can disable Switch Binding.
Message Cannot disable Insistent Domain ID while Fabric Binding is active.
Description User attempted to disable the Insistent Domain ID parameter
through the Configure Switch Parameters dialog box, but Fabric
Binding is enabled.
Action Disable Fabric Binding through the Fabric Binding dialog box before
disabling these parameters.
Message Cannot enable beaconing on a failed FRU.
Description Occurs when selecting Enable Beaconing option for a failed FRU.
Action Replace FRU and enable beaconing again or enable beaconing on
operating FRU.
Message Cannot enable beaconing while the system error light is on.
Description Beaconing cannot be enabled while the system error light is on.
Action Select Clear System Error Light from Product menu to clear error light,
then enable beaconing.
Message Cannot have spaces in field.
Description Spaces are not allowed in this field.