Module E11
Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and
RF180C
Additional indications
The displays indicate to the user the progress of a command. Error analyses are easy to perform.
Variable Description
IM_busy This bit is set when the IM processes a command. Normally, "IM_busy“ is inverted to "ready“.
IM_busy is indicated by the IM by means of the cyclical word (refer to chapter "Cyclical Control
Word between Master and MOBY IM“ under "IM_busy“). If processing takes place with the
automatic command start repeat_command, this bit indicates the processing of a new MDS with
the command that is to be executed.
command_rep_active The IM is just executing a command repetition. The bit is set as a response to the control variable
repeat_command. After init_run, FB45 first resets the command_rep_active; it is set again
delayed since FB45 first transmits the MOBY commands to the IM.
number_MDS
MOBY U/D or RF300:
The number of MDSs is indicated that are presently located in the transmission window.
If more than 15 MDSs are in the field, the display number_MDS stops at 0F hex.
error_MOBY The IM signaled this error. As a rule, this error is indicated also on the ERR LED on the IM
channel display (refer to chapter "Error Indications and Error Search“).
error_FB Error indication from FB45 (refer to chapter "Error Indications and Error Search“).
error_BUS The transmission path between FB45 and the IM signals an error. As a rule, this is a PROFIBUS
error (refer to chapter "Error Indications and Error Search“). This error is indicated by the system
functions SFC 58/59.
Display of the firmware version of the MOBY IM. The value entered here is updated after every IM
power-up . It is ASCII encoded.
Example: DBB26 DBB27
31 hex 30
hex
Version 1.0
version_MOBY
"1“ "0“
Notes
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
All other UDT 11 variables are for internal FB use only.
The user must not change them at all.