Pag e 113
Chapter 7: Command-Line Management
3. Command Syntax:
show sfp-alarm-trigger IFNAME
IFNAME specifies the name of the interface for which status and configuration information is desired.
4. Example:
The following example shows the use of show sfp-alarm-trigger to display the information of SFP alarm trigger of the interface
ge1 (port G1):
switch_a#show sfp-alarm-trigger ge1
Temperature Alarm (Warning) Threshold:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2. Usage:
Use this command to set temperature alarm (warning) threshold for SFP transceiver.
3. Command Syntax:
sfp set-temp IFNAME high-alarmhigh-warninglow alarmlow warning LEVEL
IFNAME specifies the name of the interface for which status and configuration information is desired.
LEVEL Threshold value -128 ~ 128.
4. Example:
The following example sets high temperature alarm threshold 100 for SFP transceiver of interface ge1 (port G1):
switch_a(config)#sfp set-temp ge1 high-alarm 100
switch_a(config)#
Voltage Alarm (Warning) Threshold:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2. Usage:
Use this command to set voltage alarm (warning) threshold for SFP transceiver.
3. Command Syntax:
sfp set-vcc IFNAME high-alarmhigh-warninglow alarmlow warning LEVEL
IFNAME specifies the name of the interface for which status and configuration information is desired.
LEVEL Threshold value 0 ~ 6.55 volts.
Related Manuals for Black Box computer hardware LEH1104A-4MMST