GOSSEN Foto- und Lichtmesstechnik GmbH 33
10 Technical Data
Incident light measurement (flat or spherical can be
selected)
Reflected light measurement, 20°
Digital display
Average value calculation
Flash light measurement (cord / non-cord / radio)
Display of the share of flash light as percentage
Cine meter (180° / 5° sectors)
Photometry (illuminance / luminance)
2 sbc silicon photo diodes, color-corrected
Shortest measuring
distance
Ambient light reading (at ISO 100/21°)
Incident light measurement EV -2.5 to +18.5
Reflected light measurement EV -2.5 to +18.5
Flash (at ISO 100/21°)
Incident light measurement f/1.0 to f/90
Reflected light measurement f/1.0 to f/90
+ 1 digit (= 0.1 EV/EV)
ISO 3/6° to ISO 32000/46° (in 1° DIN)
1/1, 1/2 and 1/3 steps, f-stops and times
From 1/8000 of a second to 30 minutes
Flash measuring times
(sync speeds)
From 1 second to 1/1000 of a second
Flash calculation for
altered measuring times
From 1 second to 1/1000 of a second
From 45° to 315° in 5° steps
Dynamic from EV 0 to EV 18 in 0.1EV steps
Illuminance and luminance
lx, fc, cd/m², fL
Overflow, underflow (for measurement and display)
Battery Control
User
Retractable diffuser head setting
Exposure value (EV)
Measured value correction in steps of 1/10
Status of the meter
Dynamic contrast display
0.5 to 199900 lx; 0.05 to 50000 fc
0.2 to 30000 cd/m
2
; 0.05 to 9000 fL
2.2" color TFT-LCD
Brightness settable from 50 to 100, and OFF