Qlima - Zibro kerosene heater SRE3631TC Manual

PDF Manuals
162 Pages English

Qlima - Zibro kerosene heater SRE3631TC
4
Symptoms Causes Measures to be taken
Heater doesn’t
ignite
The child safety catch lights
up
Turn the child safety catch off
The fuel in-
dicator lamp
doesn’t work
The tank is empty Fill the tank
The tank is deformed Replace the tank
Dirt particles dust or water on
the filter and / or in the fixed
tank
Clean the fixed tank and the
fuel filter.
Power loss
The fuel indicator flashes
The fuel indicator flashes Fill the tank
A poor quality fuel has been
used.
Remove the fuel from the
two tanks, then rinse with the
correct fuel.
Abnormal com-
bustion
A poor quality fuel has been
used.
Poor ventilation Ventilate regularly
Dust on the ventilator filter Clean the ventilator filter
Unpleasant
smells
A poor quality fuel has been
used
Remove the fuel from the
two tanks, then rinse with the
correct fuel.
No fuel in the tank Fill the tank
Fuel leakage or spilled fuel
Do not use any more and
contact your dealer
Fuel leakage
Move the heater, the tank is
not empty
A poor quality fuel has been
used.
AUTOMATIC DEACTIVATION
This heater is fitted with a safety system that ensures that it switches off
automatically after 36 hours continuous operation. If desired, you can switch the
heater on again by pressing the ON/OFF button
21
(see section D).
I CHILDPROOF LOCK
The childproof lock can be used to prevent children accidentally changing the
heater settings. When the heater is burning and the childproof lock is on, the heater
can only be switched off. Other functions are blocked then. If the heater has already
been switched off, the childproof lock also prevents accidental ignition of the
heater.
Activate the childproof lock by pressing the CHILDLOCK key O and holding it
down for more than 3 seconds. The childlock indicator will appear on the information
display (Fig. O), indicating that the childproof lock has been activated. Switch off the
childproof lock by pressing the CHILDLOCK key O and holding it down for more than
3 seconds once again.
J THE CORRECT USE OF ‘SAVE’
The ‘SAVE’ function allows you to limit the temperature. When this function is
activated, the heater will automatically switch off, when the room temperature exceeds
the set temperature by 3°C. Subsequently, when the room temperature has dropped
again to the set temperature, the heater will automatically switch on again.
Activate
the ‘SAVE’ setting by pressing the appropriate
22
key. The SAVE indicator light will
light up. Switch off the function by pressing the SAVE key once again.
72